NUCLEAR REGULATORY COMMISSION

10 CFR Part 72

[NRC-2022-0105]
RIN 3150-AK84


List of Approved Spent Fuel Storage Casks: Holtec International 
HI-STORM Flood/Wind Multipurpose Canister Storage System, Certificate 
of Compliance No. 1032, Amendment No. 8

AGENCY: Nuclear Regulatory Commission.

ACTION: Direct final rule.

-----------------------------------------------------------------------

SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is amending its 
spent fuel storage regulations by revising the Holtec International HI-
STORM Flood/Wind Multipurpose Canister Storage System listing within 
the ``List of approved spent fuel storage casks'' to include Amendment 
No. 8 to Certificate of Compliance No. 1032. Amendment No. 8 revises 
the description in the certificate of compliance for the Holtec 
International HI-STORM Flood/Wind system to clearly indicate that only 
the portions of the components that contact the pool water need to be 
made of stainless steel or aluminum. Amendment No. 8 also incorporates 
other minor editorial corrections.

DATES: This direct final rule is effective October 11, 2022, unless 
significant adverse comments are received by August 25, 2022. If this 
direct final rule is withdrawn as a result of such comments, timely 
notice of the withdrawal will be published in the Federal Register. 
Comments received after this date will be considered if it is practical 
to do so, but the NRC is able to ensure consideration only for comments 
received on or before this date. Comments received on this direct final 
rule will also be considered to be comments on a companion proposed 
rule published in the Proposed Rules section of this issue of the 
Federal Register.

ADDRESSES: Submit your comments, identified by Docket ID NRC-2022-0105, 
at https://www.regulations.gov. If your material cannot be submitted 
using https://www.regulations.gov, call or email the individuals listed 
in the FOR FURTHER INFORMATION CONTACT section of this document for 
alternate instructions.
    For additional direction on obtaining information and submitting 
comments, see ``Obtaining Information and Submitting Comments'' in the 
SUPPLEMENTARY INFORMATION section of this document.

FOR FURTHER INFORMATION CONTACT: William Allen, Office of Nuclear 
Material Safety and Safeguards; telephone: 301-415-6877; email: 
[email protected] or Andrew G. Carrera, Office of Nuclear Material 
Safety and Safeguards; telephone: 301-415-1078; email: 
[email protected]. Both are staff of the U.S. Nuclear Regulatory 
Commission, Washington, DC 20555-0001.

SUPPLEMENTARY INFORMATION: 

Table of Contents

I. Obtaining Information and Submitting Comments
II. Rulemaking Procedure
III. Background
IV. Discussion of Changes
V. Voluntary Consensus Standards
VI. Agreement State Compatibility
VII. Plain Writing
VIII. Environmental Assessment and Finding of No Significant Impact
IX. Paperwork Reduction Act Statement
X. Regulatory Flexibility Certification
XI. Regulatory Analysis
XII. Backfitting and Issue Finality
XIII. Congressional Review Act
XIV. Availability of Documents

I. Obtaining Information and Submitting Comments

A. Obtaining Information

    Please refer to Docket ID NRC-2022-0105 when contacting the NRC 
about the availability of information for this action. You may obtain 
publicly available information related to this action by any of the 
following methods:
     Federal Rulemaking Website: Go to https://www.regulations.gov and search for Docket ID NRC-2022-0105. Address 
questions about NRC dockets to Dawn Forder, telephone: 301-415-3407, 
email: [email protected]. For technical questions contact the 
individuals listed in the FOR FURTHER INFORMATION CONTACT section of 
this document.
     NRC's Agencywide Documents Access and Management System 
(ADAMS): You may obtain publicly available documents online in the 
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``Begin Web-based ADAMS 
Search.'' For problems with ADAMS, please contact the NRC's Public 
Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or 
by email to [email protected]. For the convenience of the reader, 
instructions about obtaining materials referenced in this document are 
provided in the ``Availability of Documents'' section.
     NRC's PDR: You may examine and purchase copies of public 
documents, by appointment, at the NRC's PDR, Room P1 B35, One White 
Flint North, 11555 Rockville Pike, Maryland 20852. To make an 
appointment to visit the PDR, please send an email to 
[email protected] or call 1-800-397-4209 or 301-415-4737, between 
8:00 a.m. and 4:00 p.m. (ET), Monday through Friday, except Federal 
holidays.

B. Submitting Comments

    Please include Docket ID NRC-2022-0105 in your comment submission. 
The NRC requests that you submit comments through the Federal 
rulemaking website at https://www.regulations.gov. If your material 
cannot be submitted using https://www.regulations.gov, call or email 
the individuals listed in the FOR FURTHER INFORMATION CONTACT section 
of this document for alternate instructions.
    The NRC cautions you not to include identifying or contact 
information that you do not want to be publicly disclosed in your 
comment submission. The NRC will post all comment submissions at 
https://www.regulations.gov as well as enter the comment submissions 
into ADAMS. The NRC does not routinely edit comment submissions to 
remove identifying or contact information.
    If you are requesting or aggregating comments from other persons 
for submission to the NRC, then you should inform those persons not to 
include identifying or contact information that they do not want to be 
publicly disclosed in their comment submission. Your request should 
state that the NRC does not routinely edit comment submissions to 
remove such information before making the comment submissions available 
to the public or entering the comment into ADAMS.

[[Page 44274]]

II. Rulemaking Procedure

    This rule is limited to the changes contained in Amendment No. 8 to 
Certificate of Compliance No. 1032 and does not include other aspects 
of the Holtec International HI-STORM Flood/Wind Multipurpose Canister 
Storage System (Holtec International HI-STORM FW) cask design. The NRC 
is using the ``direct final rule procedure'' to issue this amendment 
because it represents a limited and routine change to an existing 
certificate of compliance that is expected to be non-controversial. The 
NRC has determined that, with the requested changes, adequate 
protection of public health and safety will continue to be reasonably 
assured. The amendment to the rule will become effective on October 11, 
2022. However, if the NRC receives any significant adverse comments on 
this direct final rule by August 25, 2022, then the NRC will publish a 
document that withdraws this action and will subsequently address the 
comments received in a final rule as a response to the companion 
proposed rule published in the Proposed Rules section of this issue of 
the Federal Register. Absent significant modifications to the proposed 
revisions requiring republication, the NRC will not initiate a second 
comment period on this action.
    A significant adverse comment is a comment where the commenter 
explains why the rule would be inappropriate, including challenges to 
the rule's underlying premise or approach, or would be ineffective or 
unacceptable without a change. A comment is adverse and significant if:
    (1) The comment opposes the rule and provides a reason sufficient 
to require a substantive response in a notice-and-comment process. For 
example, a substantive response is required when:
    (a) The comment causes the NRC to reevaluate (or reconsider) its 
position or conduct additional analysis;
    (b) The comment raises an issue serious enough to warrant a 
substantive response to clarify or complete the record; or
    (c) The comment raises a relevant issue that was not previously 
addressed or considered by the NRC.
    (2) The comment proposes a change or an addition to the rule, and 
it is apparent that the rule would be ineffective or unacceptable 
without incorporation of the change or addition.
    (3) The comment causes the NRC to make a change (other than 
editorial) to the rule, certificate of compliance, or technical 
specifications.

III. Background

    Section 218(a) of the Nuclear Waste Policy Act of 1982, as amended, 
requires that ``[t]he Secretary [of the Department of Energy] shall 
establish a demonstration program, in cooperation with the private 
sector, for the dry storage of spent nuclear fuel at civilian nuclear 
power reactor sites, with the objective of establishing one or more 
technologies that the [Nuclear Regulatory] Commission may, by rule, 
approve for use at the sites of civilian nuclear power reactors 
without, to the maximum extent practicable, the need for additional 
site-specific approvals by the Commission.'' Section 133 of the Nuclear 
Waste Policy Act states, in part, that ``[t]he Commission shall, by 
rule, establish procedures for the licensing of any technology approved 
by the Commission under Section 219(a) [sic: 218(a)] for use at the 
site of any civilian nuclear power reactor.''
    To implement this mandate, the Commission approved dry storage of 
spent nuclear fuel in NRC-approved casks under a general license by 
publishing a final rule that added a new subpart K in part 72 of title 
10 of the Code of Federal Regulations (10 CFR) entitled ``General 
License for Storage of Spent Fuel at Power Reactor Sites'' (55 FR 
29181; July 18, 1990). This rule also established a new subpart L in 10 
CFR part 72 entitled ``Approval of Spent Fuel Storage Casks,'' which 
contains procedures and criteria for obtaining NRC approval of spent 
fuel storage cask designs. The NRC subsequently issued a final rule on 
March 28, 2011 (76 FR 17019), that approved the Holtec International 
HI-STORM FW System design and added it to the list of NRC-approved cask 
designs in Sec.  72.214, ``List of approved spent fuel storage casks,'' 
as Certificate of Compliance No. 1032.

IV. Discussion of Changes

    On July 30, 2021, Holtec International (the applicant) submitted an 
application to amend the HI-STORM FW System. The amendment includes the 
following changes:
     Update the HI-STORM FW System description in the 
certificate of compliance to clearly indicate that only the portions of 
the components that contact the pool water need to be made of stainless 
steel or aluminum; and
     Incorporate other minor editorial corrections.
    As documented in the preliminary safety evaluation report, the NRC 
performed a safety review of the proposed certificate of compliance 
amendment request. The NRC determined that this amendment does not 
reflect a significant change in design or fabrication of the cask. 
Specifically, the NRC determined that the design of the cask would 
continue to maintain confinement, shielding, and criticality control in 
the event of each evaluated accident condition. In addition, any 
resulting occupational exposure or offsite dose rates from the 
implementation of Amendment No. 8 would remain well within the limits 
specified by 10 CFR part 20, ``Standards for Protection Against 
Radiation.'' Therefore, the NRC found there will be no significant 
change in the types or amounts of any effluent released, no significant 
increase in the individual or cumulative radiation exposure, and no 
significant increase in the potential for or consequences from 
radiological accidents.
    The NRC determined that the amended Holtec International HI-STORM 
FW System cask design, when used under the conditions specified in the 
certificate of compliance, the technical specifications, and the NRC's 
regulations, will meet the requirements of 10 CFR part 72; therefore, 
adequate protection of public health and safety will continue to be 
reasonably assured. When this direct final rule becomes effective, 
persons who hold a general license under Sec.  72.210 may, consistent 
with the license conditions under Sec.  72.212, load spent nuclear fuel 
into Holtec International HI-STORM FW System casks that meet the 
criteria of Amendment No. 8 to Certificate of Compliance No. 1032.

V. Voluntary Consensus Standards

    The National Technology Transfer and Advancement Act of 1995 (Pub. 
L. 104-113) requires that Federal agencies use technical standards that 
are developed or adopted by voluntary consensus standards bodies unless 
the use of such a standard is inconsistent with applicable law or 
otherwise impractical. In this direct final rule, the NRC revises the 
Holtec International HI-STORM FW System cask design listed in Sec.  
72.214. This action does not constitute the establishment of a standard 
that contains generally applicable requirements.

VI. Agreement State Compatibility

    Under the ``Agreement State Program Policy Statement'' approved by 
the Commission on October 2, 2017, and published in the Federal 
Register on October 18, 2017 (82 FR 48535), this rule is classified as 
Compatibility Category NRC--Areas of Exclusive NRC Regulatory 
Authority. The NRC program elements in this category are those that 
relate directly to areas of regulation

[[Page 44275]]

reserved to the NRC by the Atomic Energy Act of 1954, as amended, or 
the provisions of 10 CFR chapter I. Therefore, compatibility is not 
required for program elements in this category. Although an Agreement 
State may not adopt program elements reserved to the NRC, and the 
Category ``NRC'' does not confer regulatory authority on the State, the 
State may wish to inform its licensees of certain requirements by means 
consistent with the particular State's administrative procedure laws.

VII. Plain Writing

    The Plain Writing Act of 2010 (Pub. L. 111-274) requires Federal 
agencies to write documents in a clear, concise, and well-organized 
manner. The NRC wrote this document to be consistent with the Plain 
Writing Act as well as the Presidential Memorandum, ``Plain Language in 
Government Writing,'' published June 10, 1998 (63 FR 31885).

VIII. Environmental Assessment and Finding of No Significant Impact

    Under the National Environmental Policy Act of 1969, as amended, 
and the NRC's regulations in 10 CFR part 51, ``Environmental Protection 
Regulations for Domestic Licensing and Related Regulatory Functions,'' 
the NRC has determined that this direct final rule, if adopted, would 
not be a major Federal action significantly affecting the quality of 
the human environment and, therefore, an environmental impact statement 
is not required. The NRC has made a finding of no significant impact on 
the basis of this environmental assessment.

A. The Action

    The action is to amend Sec.  72.214 to revise the Holtec 
International HI-STORM FW System listing within the ``List of approved 
spent fuel storage casks'' to include Amendment No. 8 to Certificate of 
Compliance No. 1032.

B. The Need for the Action

    This direct final rule amends the certificate of compliance for the 
Holtec International HI-STORM FW System within the list of approved 
spent fuel storage casks to allow power reactor licensees to store 
spent fuel at reactor sites in casks with the approved modifications 
under a general license. Specifically, Amendment No. 8 revises the 
certificate of compliance as described in Section IV, ``Discussion of 
Changes,'' of this document, for the use of the Holtec International 
HI-STORM FW System.

C. Environmental Impacts of the Action

    On July 18,1990 (55 FR 29181), the NRC issued an amendment to 10 
CFR part 72 to provide for the storage of spent fuel under a general 
license in cask designs approved by the NRC. The potential 
environmental impact of using NRC-approved storage casks was analyzed 
in the environmental assessment for the 1990 final rule. The 
environmental assessment for this Amendment No. 8 tiers off of the 
environmental assessment for the July 18, 1990, final rule. Tiering off 
past environmental assessments is a standard process under the National 
Environmental Policy Act of 1969, as amended.
    The Holtec International HI-STORM FW System is designed to mitigate 
the effects of design basis accidents that could occur during storage. 
Design basis accidents account for human-induced events and the most 
severe natural phenomena reported for the site and surrounding area. 
Postulated accidents analyzed for an independent spent fuel storage 
installation, the type of facility at which a holder of a power reactor 
operating license would store spent fuel in casks in accordance with 10 
CFR part 72, can include tornado winds and tornado-generated missiles, 
a design basis earthquake, a design basis flood, an accidental cask 
drop, lightning effects, fire, explosions, and other incidents.
    This amendment does not reflect a significant change in design or 
fabrication of the cask. Because there are no significant design or 
process changes, any resulting occupational exposure or offsite dose 
rates from the implementation of Amendment No. 8 would remain well 
within the 10 CFR part 20 limits. The NRC has also determined that the 
design of the cask as modified by this rule would still maintain 
confinement, shielding, and criticality control in the event of an 
accident. Therefore, the proposed changes will not result in any 
radiological or non-radiological environmental impacts that 
significantly differ from the environmental impacts evaluated in the 
environmental assessment supporting the July 18, 1990, final rule. 
There will be no significant change in the types or the amounts of any 
effluent released, no significant increase in the individual or 
cumulative radiation exposures, and no significant increase in the 
potential for, or consequences from, radiological accidents. The NRC 
documented its safety findings in the preliminary safety evaluation 
report.

D. Alternative to the Action

    The alternative to this action is to deny approval of Amendment No. 
8 and not issue the direct final rule. Consequently, any 10 CFR part 72 
general licensee that seeks to load spent nuclear fuel into the Holtec 
International HI-STORM FW System in accordance with the changes 
described in proposed Amendment No. 8 would have to request an 
exemption from the requirements of Sec. Sec.  72.212 and 72.214. Under 
this alternative, interested licensees would have to prepare, and the 
NRC would have to review, a separate exemption request, thereby 
increasing the administrative burden upon the NRC and the costs to each 
licensee. The environmental impacts would be the same as the proposed 
action.

E. Alternative Use of Resources

    Approval of Amendment No. 8 to Certificate of Compliance No. 1032 
would result in no irreversible commitment of resources.

F. Agencies and Persons Contacted

    No agencies or persons outside the NRC were contacted in connection 
with the preparation of this environmental assessment.

G. Finding of No Significant Impact

    The environmental impacts of the action have been reviewed under 
the requirements in the National Environmental Policy Act of 1969, as 
amended, and the NRC's regulations in subpart A of 10 CFR part 51, 
``Environmental Protection Regulations for Domestic Licensing and 
Related Regulatory Functions.'' Based on the foregoing environmental 
assessment, the NRC concludes that this direct final rule, ``List of 
Approved Spent Fuel Storage Casks: Holtec International HI-STORM Flood/
Wind Multipurpose Canister Storage System, Certificate of Compliance 
No. 1032, Amendment No. 8,'' will not have a significant effect on the 
human environment. Therefore, the NRC has determined that an 
environmental impact statement is not necessary for this direct final 
rule.

IX. Paperwork Reduction Act Statement

    This direct final rule does not contain any new or amended 
collections of information subject to the Paperwork Reduction Act of 
1995 (44 U.S.C. 3501 et seq.). Existing collections of information were 
approved by the Office of Management and Budget, approval number 3150-
0132.

[[Page 44276]]

Public Protection Notification

    The NRC may not conduct or sponsor, and a person is not required to 
respond to, a request for information or an information collection 
requirement unless the requesting document displays a currently valid 
Office of Management and Budget control number.

X. Regulatory Flexibility Certification

    Under the Regulatory Flexibility Act of 1980 (5 U.S.C. 605(b)), the 
NRC certifies that this direct final rule will not, if issued, have a 
significant economic impact on a substantial number of small entities. 
This direct final rule affects only nuclear power plant licensees and 
Holtec International. These entities do not fall within the scope of 
the definition of small entities set forth in the Regulatory 
Flexibility Act or the size standards established by the NRC (Sec.  
2.810).

XI. Regulatory Analysis

    On July 18, 1990 (55 FR 29181), the NRC issued an amendment to 10 
CFR part 72 to provide for the storage of spent nuclear fuel under a 
general license in cask designs approved by the NRC. Any nuclear power 
reactor licensee can use NRC-approved cask designs to store spent 
nuclear fuel if (1) it notifies the NRC in advance; (2) the spent fuel 
is stored under the conditions specified in the cask's certificate of 
compliance; and (3) the conditions of the general license are met. A 
list of NRC-approved cask designs is contained in Sec.  72.214. On 
March 28, 2011 (76 FR 17019), the NRC issued an amendment to 10 CFR 
part 72 that approved the Holtec International HI-STORM FW System 
design by adding it to the list of NRC-approved cask designs in Sec.  
72.214. On July 30, 2021, Holtec International submitted a request to 
amend the Holtec International HI-STORM FW System as described in 
Section IV, ``Discussion of Changes,'' of this document.
    The alternative to this action is to withhold approval of Amendment 
No. 8 and to require any 10 CFR part 72 general licensee seeking to 
load spent nuclear fuel into Holtec International HI-STORM FW System 
under the changes described in Amendment No. 8 to request an exemption 
from the requirements of Sec. Sec.  72.212 and 72.214. Under this 
alternative, each interested 10 CFR part 72 licensee would have to 
prepare, and the NRC would have to review, a separate exemption 
request, thereby increasing the administrative burden upon the NRC and 
the costs to each licensee.
    Approval of this direct final rule is consistent with previous NRC 
actions. Further, as documented in the preliminary safety evaluation 
report and environmental assessment, this direct final rule will have 
no adverse effect on public health and safety or the environment. This 
direct final rule has no significant identifiable impact or benefit on 
other government agencies. Based on this regulatory analysis, the NRC 
concludes that the requirements of this direct final rule are 
commensurate with the NRC's responsibilities for public health and 
safety and the common defense and security. No other available 
alternative is believed to be as satisfactory; therefore, this action 
is recommended.

XII. Backfitting and Issue Finality

    The NRC has determined that the backfit rule (Sec.  72.62) does not 
apply to this direct final rule. Therefore, a backfit analysis is not 
required. This direct final rule revises Certificate of Compliance No. 
1032 for the Holtec International HI-STORM FW System, as currently 
listed in Sec.  72.214. The revision consists of the changes in 
Amendment No. 8 previously described, as set forth in the revised 
certificate of compliance and technical specifications.
    Amendment No. 8 to Certificate of Compliance No. 1032 for the 
Holtec International HI-STORM FW System was initiated by Holtec 
International and was not submitted in response to new NRC 
requirements, or an NRC request for amendment. Amendment No. 8 applies 
only to new casks fabricated and used under Amendment No. 8. These 
changes do not affect existing users of the Holtec International HI-
STORM FW System, and the current Amendment No. 5 continues to be 
effective for existing users. Amendment Nos. 6 and 7 to Certificate of 
Compliance No. 1032 have not been issued. While current users of this 
storage system may comply with the new requirements in Amendment No. 8, 
this would be a voluntary decision on the part of current users.
    For these reasons, Amendment No. 8 to Certificate of Compliance No. 
1032 does not constitute backfitting under Sec.  72.62 or Sec.  
50.109(a)(1), or otherwise represent an inconsistency with the issue 
finality provisions applicable to combined licenses in 10 CFR part 52. 
Accordingly, the NRC has not prepared a backfit analysis for this 
rulemaking.

XIII. Congressional Review Act

    This direct final rule is not a rule as defined in the 
Congressional Review Act.

XIV. Availability of Documents

    The documents identified in the following table are available to 
interested persons, as indicated.

----------------------------------------------------------------------------------------------------------------
                          Document                              ADAMS accession No./ Federal Register citation
----------------------------------------------------------------------------------------------------------------
Direct Final Rule, 10 CFR Part 72, ``List of Approved Spent  76 FR 17019.
 Fuel Storage Casks: Holtec International HI-STORM Flood/
 Wind System, Certificate of Compliance No. 1032; [NRC-2011-
 0007] RIN 3150-AI90, March 28, 2011.
Application from Holtec International for Certificate of     ML21211A608 (package).
 Compliance No. 1032, Amendment No. 8, to HI-STORM FW
 System, July 30, 2021.
User Need Memorandum Package to J. Shepherd from Y. Diaz-    ML22019A111 (package).
 Sanabria with Proposed Certificate of Compliance No. 1032,
 Amendment No. 8; Associated Proposed Technical
 Specifications; Appendices A and B; and the Preliminary
 Safety Evaluation Report, April 6, 2022.
----------------------------------------------------------------------------------------------------------------

    The NRC may post materials related to this document, including 
public comments, on the Federal rulemaking website at https://www.regulations.gov under Docket ID NRC-2022-0105. In addition, the 
Federal rulemaking website allows members of the public to receive 
alerts when changes or additions occur in a docket folder. To 
subscribe: (1) navigate to the docket folder (NRC-2022-0105); (2) click 
the ``Subscribe'' link; and (3) enter an email address and click on the 
``Subscribe'' link.

List of Subjects in 10 CFR Part 72

    Administrative practice and procedure, Hazardous waste, Indians, 
Intergovernmental relations, Nuclear energy, Penalties, Radiation 
protection, Reporting and recordkeeping requirements, Security 
measures, Spent fuel, Whistleblowing.

    For the reasons set out in the preamble and under the authority of 
the Atomic Energy Act of 1954, as amended; the Energy Reorganization 
Act of 1974, as amended; the Nuclear Waste Policy

[[Page 44277]]

Act of 1982, as amended; and 5 U.S.C. 552 and 553; the NRC is adopting 
the following amendments to 10 CFR part 72:

PART 72--LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF 
SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-
RELATED GREATER THAN CLASS C WASTE

0
1. The authority citation for part 72 continues to read as follows:

    Authority:  Atomic Energy Act of 1954, secs. 51, 53, 57, 62, 63, 
65, 69, 81, 161, 182, 183, 184, 186, 187, 189, 223, 234, 274 (42 
U.S.C. 2071, 2073, 2077, 2092, 2093, 2095, 2099, 2111, 2201, 2210e, 
2232, 2233, 2234, 2236, 2237, 2238, 2273, 2282, 2021); Energy 
Reorganization Act of 1974, secs. 201, 202, 206, 211 (42 U.S.C. 
5841, 5842, 5846, 5851); National Environmental Policy Act of 1969 
(42 U.S.C. 4332); Nuclear Waste Policy Act of 1982, secs. 117(a), 
132, 133, 134, 135, 137, 141, 145(g), 148, 218(a) (42 U.S.C. 
10137(a), 10152, 10153, 10154, 10155, 10157, 10161, 10165(g), 10168, 
10198(a)); 44 U.S.C. 3504 note.


0
2. In Sec.  72.214, revise Certificate of Compliance No. 1032 to read 
as follows:


Sec.  72.214   List of approved spent fuel storage casks.

* * * * *
    Certificate Number: 1032.
    Initial Certificate Effective Date: June 13, 2011, superseded by 
Amendment Number 0, Revision 1, on April 25, 2016.
    Amendment Number 0, Revision 1, Effective Date: April 25, 2016.
    Amendment Number 1 Effective Date: December 17, 2014, superseded by 
Amendment Number 1, Revision 1, on June 2, 2015.
    Amendment Number 1, Revision 1, Effective Date: June 2, 2015.
    Amendment Number 2 Effective Date: November 7, 2016.
    Amendment Number 3 Effective Date: September 11, 2017.
    Amendment Number 4 Effective Date: July 14, 2020.
    Amendment Number 5 Effective Date: July 27, 2020.
    Amendment Number 6 [Reserved]
    Amendment Number 7 [Reserved]
    Amendment Number 8 Effective Date: October 11, 2022.
    SAR Submitted by: Holtec International.
    SAR Title: Final Safety Analysis Report for the HI-STORM FW System.
    Docket Number: 72-1032.
    Certificate Expiration Date: June 12, 2031.
    Model Number: HI-STORM FW MPC-37, MPC-89.
* * * * *

    Dated: July 13, 2022.

    For the Nuclear Regulatory Commission.
Daniel H. Dorman,
Executive Director for Operations.
[FR Doc. 2022-15939 Filed 7-25-22; 8:45 am]