NUCLEAR REGULATORY COMMISSION
[Docket Nos. 72-37, 50-237, and 50-249; NRC-2024-0054]
Constellation Energy Generation, LLC; Dresden Nuclear Power
Station, Unit 2 and Unit 3; Independent Spent Fuel Storage
Installation; Exemption
AGENCY: Nuclear Regulatory Commission.
ACTION: Notice; issuance.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) issued an
exemption to Constellation Energy Generation, LLC permitting Dresden
Nuclear Power Station (Dresden) to maintain loaded and to load 68M
multi-purpose canisters with continuous basket shims in the HI-STORM
100 Cask System at its Dresden Unit 2 and Unit 3 independent spent fuel
storage installation in a storage condition where the terms,
conditions, and specifications in the Certificate of Compliance No.
1014, Amendment No. 8, Revision No. 1 are not met.
DATES: The exemption was issued on April 1, 2024.
ADDRESSES: Please refer to Docket ID NRC-2024-0054 when contacting the
NRC about the availability of
[[Page 24880]]
information regarding this document. You may obtain publicly available
information related to this document using any of the following
methods:
Federal Rulemaking Website: Go to https://www.regulations.gov and search for Docket ID NRC-2024-0054. Address
questions about Docket IDs in Regulations.gov to Stacy Schumann;
telephone: 301-415-0624; email: [email protected]. For technical
questions, contact the individual listed in the For Further Information
Contact section of this document.
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly available documents online in the
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``Begin Web-based ADAMS
Search.'' For problems with ADAMS, please contact the NRC's Public
Document Room (PDR) reference staff at 1-800-397-4209, at 301-415-4737,
or by email to [email protected]. The ADAMS accession number for
each document referenced (if it is available in ADAMS) is provided the
first time that it is mentioned in this document.
NRC's PDR: The PDR, where you may examine and order copies
of publicly available documents, is open by appointment. To make an
appointment to visit the PDR, please send an email to
[email protected] or call 1-800-397-4209 or 301-415-4737, between 8
a.m. and 4 p.m. eastern time (ET), Monday through Friday, except
Federal holidays.
FOR FURTHER INFORMATION CONTACT: Yen-Ju Chen, Office of Nuclear
Material Safety and Safeguards, U.S. Nuclear Regulatory Commission,
Washington, DC 20555; telephone: 301-415-1018; email: [email protected].
SUPPLEMENTARY INFORMATION: The text of the exemption is attached.
Dated: April 3, 2024.
For the Nuclear Regulatory Commission.
Yoira K. Diaz-Sanabria,
Chief, Storage and Transportation Licensing Branch, Division of Fuel
Management, Office of Nuclear Material Safety, and Safeguards.
Attachment--Exemption
NUCLEAR REGULATORY COMMISSION
Docket Nos. 72-37, 50-237, and 50-249
Constellation Energy Generation, LLC; Dresden Nuclear Power Station
Unit 2 and Unit 3; Independent Spent Fuel Storage Installation
I. Background
Constellation Energy Generation, LLC (Constellation) is the holder
of Renewed Facility Operating License Nos. DPR-19 and DPR-25, which
authorize operation of the Dresden Nuclear Power Station, Unit 2 and
Unit 3 (Dresden) in Morris, Illinois, pursuant to Part 50 of Title 10
of the Code of Federal Regulations (10 CFR), ``Domestic Licensing of
Production and Utilization Facilities.'' The licenses provide, among
other things, that the facility is subject to all rules, regulations,
and orders of the U.S. Nuclear Regulatory Commission (NRC) now or
hereafter in effect.
Consistent with 10 CFR part 72, subpart K, ``General License for
Storage of Spent Fuel at Power Reactor Sites,'' a general license is
issued for the storage of spent fuel in an Independent Spent Fuel
Storage Installation (ISFSI) at power reactor sites to persons
authorized to possess or operate nuclear power reactors under 10 CFR
part 50. Constellation is authorized to operate nuclear power reactors
under 10 CFR part 50 and holds a 10 CFR part 72 general license for
storage of spent fuel at the Dresden ISFSI. Under the terms of the
general license, Constellation stores spent fuel at its Dresden ISFSI
using the HI-STORM 100 Cask System in accordance with Certificate of
Compliance (CoC) No. 1014, Amendment No. 8, Revision No. 1.
II. Request/Action
By a letter dated February 23, 2024 (Agencywide Documents Access
and Management System [ADAMS] Accession No. ML24054A031), and
supplemented on February 28, 2024 (ML24065A292) and March 8, 2024
(ML24068A069), Constellation requested an exemption from the
requirements of 10 CFR 72.212(a)(2), 72.212(b)(3), 72.212(b)(5)(i),
72.212(b)(11), and 72.214 that require Dresden to comply with the
terms, conditions, and specifications of the CoC No. 1014, Amendment
No. 8, Revision No. 1 (ML16041A233). If approved, Constellation's
exemption request would accordingly allow Dresden to maintain loaded
and to load Multi-Purpose Canisters (MPC) with an unapproved, variant
basket design (i.e., MPC-68M-CBS) in the HI-STORM 100 Cask System, and
thus, to load the systems in a storage condition where the terms,
conditions, and specifications in the CoC No. 1014, Amendment No. 8,
Revision No. 1 are not met.
Constellation currently uses the HI-STORM 100 Cask System under CoC
No. 1014, Amendment No. 8, Revision No. 1, for dry storage of spent
nuclear fuel in MPC-68M at the Dresden ISFSI. Holtec International
(Holtec), the designer and manufacturer of the HI-STORM 100 Cask
System, developed a variant of the design with continuous basket shims
(CBS) for the MPC-68M, known as MPC-68M-CBS. Holtec performed a non-
mechanistic tip-over analysis with favorable results and implemented
the CBS variant design under the provisions of 10 CFR 72.48, ``Changes,
tests, and experiments,'' which allows licensees to make changes to
cask designs without a CoC amendment under certain conditions (listed
in 10 CFR 72.48(c)). After evaluating the specific changes to the cask
designs, the NRC determined that Holtec erred when it implemented the
CBS variant design under 10 CFR 72.48, as this is not the type of
change allowed without a CoC amendment. For this reason, the NRC issued
three Severity Level IV violations to Holtec (ML24016A190).
Prior to the issuance of the violations, Constellation had loaded
four MPC-68M-CBS in the HI-STORM 100 Cask System, which are safely in
storage at the Dresden ISFSI. Constellation's near-term loading
campaigns for the Dresden ISFSI include plans to load one MPC-68M-CBS
in the HI-STORM 100 Cask System in May 2024 and four MPC-68M-CBS in
March 2025. While Holtec was required to submit a CoC amendment to the
NRC to seek approval of the CBS variant design, such a process will not
be completed in time to inform decisions for these near-term loading
campaigns. Therefore, Constellation submitted this exemption request in
order to allow for the continued storage of the four already loaded
MPC-68M-CBS, and future loadings of one MPC-68M-CBS in May 2024 and
four in March 2025, at the Dresden ISFSI. This exemption is limited to
the use of MPC-68M-CBS in the HI-STORM 100 Cask System only for the
four already loaded systems and specific near-term planned loadings of
five systems using the MPC-68M-CBS variant basket design.
III. Discussion
Pursuant to 10 CFR 72.7, ``Specific exemptions,'' the Commission
may, upon application by any interested person or upon its own
initiative, grant such exemptions from the requirements of the
regulations of 10 CFR part 72 as it determines are authorized by law
and will not endanger life or property or the common defense and
security and are otherwise in the public interest.
A. The Exemption Is Authorized by Law
This exemption would allow Constellation to maintain loaded and to
load MPC-68M-CBS in the HI-STORM 100 Cask System at its Dresden ISFSI
in a storage condition where the terms,
[[Page 24881]]
conditions, and specifications in the CoC No. 1014, Amendment No. 8,
Revision No. 1, are not met. Constellation is requesting an exemption
from the provisions in 10 CFR part 72 that require the licensee to
comply with the terms, conditions, and specifications of the CoC for
the approved cask model it uses. Section 72.7 allows the NRC to grant
exemptions from the requirements of 10 CFR part 72. This authority to
grant exemptions is consistent with the Atomic Energy Act of 1954, as
amended, and is not otherwise inconsistent with NRC's regulations or
other applicable laws. Additionally, no other law prohibits the
activities that would be authorized by the exemption. Therefore, the
NRC concludes that there is no statutory prohibition on the issuance of
the requested exemption, and the NRC is authorized to grant the
exemption by law.
B. The Exemption Will Not Endanger Life or Property or the Common
Defense and Security
This exemption would allow Constellation to maintain loaded and to
load MPC-68M-CBS in the HI-STORM 100 Cask System at the Dresden ISFSI
in a storage condition where the terms, conditions, and specifications
in the CoC No. 1014, Amendment No. 8, Revision No. 1, are not met. In
support of its exemption request, Constellation asserts that issuance
of the exemption would not endanger life or property because the
administrative controls the applicant has in place prevent a tip-over
or handling event, and that the containment boundary would be
maintained in such an event. Constellation relies, in part, on the
approach in the NRC's Safety Determination Memorandum (ML24018A085).
The NRC issued this Safety Determination Memorandum to address whether,
with respect to the enforcement action against Holtec regarding this
violation, there was any need to take an immediate action for the cask
systems that were already loaded with non-compliant basket designs. The
Safety Determination Memorandum documents a risk-informed approach
concluding that, during the design basis event of a non-mechanistic
tip-over, the fuel in the basket in the MPC-68M-CBS remains in a
subcritical condition.
Constellation also provided site-specific technical information, as
supplemented, including information explaining why the use of the
approach in the NRC's Safety Determination Memorandum is appropriate
for determining the safe use of the CBS variant baskets at the Dresden
ISFSI. Specifically, Constellation described that the analysis of the
tip-over design basis event that is relied upon in the NRC's Safety
Determination Memorandum, which demonstrates that the MPC confinement
barrier is maintained, is documented in the updated final safety
analysis report (UFSAR) for the HI-STORM 100 Cask System CoC No. 1014,
Amendment 8, Revision No. 1 that is used at the Dresden site.
Constellation also described its administrative controls for handling
of the HI-STORM 100 Cask System at the Dresden ISFSI to prevent a tip-
over or handling event. Those controls include operational procedures
that demonstrate that the system is handled with a single failure proof
device, complying with ANSI N14.6, ``for Radioactive Materials--Special
Lifting Devices for Shipping Containers Weighing 10 000 Pounds (4500
kg) or More,'' and consistent with NUREG-612, ``Control of Heavy Loads
at Nuclear Power Plants,'' (ML070250180) for heavy load lifting
component, inside of the Reactor Buildings and during transport to the
ISFSI. In addition, the transporter includes redundant drop protection.
Additionally, Constellation provided specific information from
Dresden's 72.212 Evaluation Report, Revision 15, indicating that during
the design basis event of a non-mechanistic tip-over, Dresden's ISFSI
would meet the requirements in 10 CFR 72.104, ``Criteria for
radioactive materials in effluents and direct radiation from an ISFSI
or MRS,'' and 72.106, ``Controlled area of an ISFSI or MRS.''
Specifically, Constellation described that, in the highly unlikely
event of a tip-over, any potential fuel damage from a non-mechanistic
tip-over event would be localized, the confinement barrier would be
maintained, and the shielding material would remain intact. Coupled
with the distance of the Dresden ISFSI to the site area boundary,
Constellation concluded that compliance with 72.104 and 72.106 is not
impacted by approving this exemption request.
The NRC staff reviewed the information provided by Constellation
and concludes that issuance of the exemption would not endanger life or
property because the administrative controls Constellation has in place
at the Dresden ISFSI sufficiently minimize the possibility of a tip-
over or handling event, and that the containment boundary would be
maintained in such an event. The staff confirmed that these
administrative controls comply with the technical specifications and
UFSAR for the HI-STORM 100 Cask System CoC No. 1014, Amendment 8,
Revision No. 1 that is used at the Dresden site. In addition, the staff
confirmed that the information provided by Constellation regarding
Dresden's 72.212 Evaluation Report, Revision 15, demonstrates that the
consequences of normal and accident conditions would be within the
regulatory limits of the 10 CFR 72.104 and 10 CFR 72.106. The staff
also determined that the requested exemption is not related to any
aspect of the physical security or defense of the Dresden ISFSI;
therefore, granting the exemption would not result in any potential
impacts to common defense and security.
For these reasons, the NRC staff has determined that under the
requested exemption, the storage system will continue to meet the
safety requirements of 10 CFR part 72 and the offsite dose limits of 10
CFR part 20 and, therefore, will not endanger life or property or the
common defense and security.
C. The Exemption Is Otherwise in the Public Interest
The proposed exemption would allow the four already loaded MPC-68M-
CBS in the HI-STORM 100 Cask System to remain in storage at the Dresden
ISFSI, and allow Constellation to load one MPC-68M-CBS in the HI-STORM
100 Cask System in May 2024 and four MPC-68M-CBS in March 2025,at the
Dresden ISFSI, even though the CBS variant basket design is not part of
the approved CoC No. 1014, Amendment No. 8, Revision No. 1. According
to Constellation, the exemption is in the public interest because
unloading fuel from already loaded canisters and not being able to load
fuel into dry storage in future loading campaigns would impact
Constellation's ability to offload fuel from the Dresden reactor units,
consequently impacting continued safe reactor operation. The reflooding
of the MPCs, removal of fuel assemblies, and replacement into a
different MPC would result in additional doses and handling operations
with no added safety benefit. In addition, future loading campaigns
would need to be delayed until older design canisters can be fabricated
and delivered to the site.
Constellation stated that to unload already loaded MPC-68M-CBS or
delay the future loading campaigns would impact the ability to
effectively manage the margin to full core discharge capacity in the
Dresden Unit 2 and Unit 3 spent fuel pools. The low spent fuel pool
capacity would make it difficult to refuel and present potential risks
to fuel handling operations during pre- and post-outage. In addition, a
crowded spent fuel pool would challenge the
[[Page 24882]]
decay heat removal demand of the pool and increase the likelihood of a
loss of fuel pool cooling event and a fuel handling accident.
Furthermore, Dresden planned the cask loading campaigns years in
advance based on availability of the specialized workforce and
equipment that is shared throughout the Constellation fleet. These
specialty resources support competing priorities including refueling
outages, loading campaigns, fuel pool cleanouts, fuel inspections, fuel
handing equipment upgrade and maintenance, fuel sipping, new fuel
receipt, and crane maintenance and upgrades. Any delays would have a
cascading impact on other scheduled specialized activities.
For the reasons described by Constellation in the exemption
request, the NRC agrees that it is in the public interest to grant the
exemption. If the exemption is not granted, in order to comply with the
CoC, Constellation would have to unload MPC-68M-CBS from the HI-STORM
100 Cask System at the Dresden ISFSI and reload into the older design
MPC-68M to restore compliance with terms, conditions, and
specifications of the CoC. This would subject onsite personnel to
additional radiation exposure, increase the risk of a possible fuel
handling accident, and increase the risk of a possible heavy load
handling accident. Furthermore, the removed spent fuel would need to be
placed in the spent fuel pool until it can be loaded into another
storage cask or remain in the spent fuel pool if it is not permitted to
be loaded into casks for future loading campaigns. As described by
Constellation, this scenario would affect Constellation's ability to
effectively manage the spent pool capacity and reactor fuel offloading
at Dresden. In addition, the rescheduling of the specialized resources
for the future loading campaigns would impact the operations of Dresden
and other Constellation sites.
Therefore, the staff concludes that approving the exemption is in
the public interest.
Environmental Consideration
The NRC staff also considered whether there would be any
significant environmental impacts associated with the exemption. For
this proposed action, the NRC staff performed an environmental
assessment pursuant to 10 CFR 51.30. The environmental assessment
concluded that the proposed action would not significantly impact the
quality of the human environment. The NRC staff concluded that the
proposed action would not result in any changes in the types or amounts
of any radiological or non-radiological effluents that may be released
offsite, and there would be no significant increase in occupational or
public radiation exposure because of the proposed action. The
environmental assessment and the finding of no significant impact was
published on April 1, 2024 (89 FR 22463).
IV. Conclusion
Based on these considerations, the NRC has determined that,
pursuant to 10 CFR 72.7, the exemption is authorized by law, will not
endanger life or property or the common defense and security, and is
otherwise in the public interest. Therefore, the NRC grants
Constellation an exemption from the requirements of Sec. Sec.
72.212(a)(2), 72.212(b)(3), 72.212(b)(5)(i), 72.212(b)(11), and 72.214
with respect to the ongoing storage of four MPC-68M-CBS in the HI-STORM
100 Cask System and future loading in the HI-STORM 100 Cask System of
one MPC-68M-CBS in May 2024 and four MPC-68M-CBS in March 2025.
This exemption is effective upon issuance.
Dated: April 1, 2024.
For the Nuclear Regulatory Commission.
/RA/
Yoira K. Diaz-Sanabria,
Chief, Storage and Transportation Licensing Branch, Division of Fuel
Management, Office of Nuclear Material Safety, and Safeguards.
[FR Doc. 2024-07455 Filed 4-8-24; 8:45 am]